No Touchy! When Your Diabetes Device and Your Skin Just Can’t Get Along…
CGMs and insulin pumps are lifesavers. Yet, many of us discover that while our diabetes loves the technology, our skin has other plans.
Redness. Itching. Burning. Rashes. Tiny bumps that seem to appear overnight.
If you’ve ever removed a sensor or infusion set and thought, “Well, that doesn’t look right,” you’re not alone.
Recent research presented at the 2026 European Academy of Allergy and Clinical Immunology (EAACI) Congress found that skin reactions from wearable diabetes devices are surprisingly common—and often linked to a handful of repeat-offending allergens hiding in device adhesives and components.
What Diabetes Device is Causing Skin Irritation?
Researchers evaluated 45 youth with type 1 diabetes who experienced dermatitis from a CGM or insulin pump. Using patch testing, they found that over 60% tested positive for at least one allergen.
The biggest troublemaker?
Colophony (Rosin)
A natural resin derived from pine and other conifer trees. I had no idea they used actual tree sap!
Despite sounding harmless, colophony was identified in more than half of allergic contact dermatitis cases and has become one of the most frequently reported causes of device-related skin reactions.
Colophony isn’t just found in diabetes device adhesives. It’s also used in a variety of everyday products, including some bandages, cosmetics, personal care products, paints, varnishes, and industrial adhesives. So if you’ve ever noticed your skin reacting to other sticky products, your CGM or pump adhesive may not be the first offender—it may simply be introducing you to an allergy you didn’t know you had!
Other common offenders included:
- Nickel
- Ethyl cyanoacrylate (a fast-acting adhesive component)
- Balsam of Peru (a fragrance and resin compound)
- Phenol-formaldehyde resin
These substances may be found not only in the adhesive that sticks the device to the skin but also in components used to manufacture the device itself.

The Adhesive Hall of Shame
Allergen | Common Use | % of Allergic Cases |
Colophony (Rosin) | Adhesives and coatings | 57% |
Nickel | Device components | 25% |
Ethyl Cyanoacrylate | Fast-acting adhesives | 18% |
Balsam of Peru | Fragrances and resins | 14% |
Phenol-Formaldehyde Resin | Adhesives and coatings | 11% |
Skin Irritation or Allergy?
Not every rash is an allergy.
Healthcare providers generally think about skin reactions in two categories:
Irritant Contact Dermatitis
This occurs when the skin becomes irritated from friction, moisture, sweat, adhesive removal, or prolonged wear.
Common signs:
- Mild redness
- Dry or flaky skin
- Burning sensation
- Symptoms shortly after applying a device
Allergic Contact Dermatitis
This occurs when the immune system develops sensitivity to a specific chemical.
Common signs:
- Significant itching
- Persistent rash
- Swelling
- Reactions that worsen over time
- Symptoms appearing after weeks or months of successful wear
Interestingly, the study found that reactions developing after one month of device use were more likely to represent true allergic contact dermatitis. Early reactions were more likely to be irritation from friction, sweat, moisture, or prolonged adhesive exposure.
And This Matters Because…
Skin irritation isn’t just annoying—it can affect diabetes management.
When wear becomes uncomfortable, people may:
- Remove devices early
- Delay replacing sensors
- Avoid rotating sites
- Stop using helpful technology altogether
This can lead to less glucose data, interrupted insulin delivery, and potentially poorer glycemic outcomes. When we begin to lose confidence in our devices, diabetes management becomes more uncertain, frustrating, and sometimes even scary.
What Can We Do?
The ideal solution would be improved products with fewer allergenic ingredients. Until then, there are several strategies that may help.
Before Application
✓ Start with clean, dry skin
✓ Allow alcohol wipes to dry completely
✓ Avoid applying immediately after lotions or moisturizers
✓ Consider an antiperspirant spray if sweating is a frequent issue
Create a Barrier
Many people successfully use:
- Barrier wipes
- Barrier films
- Hydrocolloid dressings
- Transparent dressings with a small opening cut for the sensor or cannula
These approaches may help reduce direct skin contact with adhesives.
If reactions continue, your healthcare provider may recommend:
- Patch testing
- Prescription topical treatments
- Alternative device options
- Different insertion sites
Because manufacturers use different adhesive formulations—and sometimes change them over time—switching devices can occasionally make a significant difference.
It’s a Touchy Situation
Today’s diabetes technology offers incredible benefits, but even the smartest sensor can’t help much if your skin refuses to cooperate.
If your device site is itchy, angry, or looking like it picked a fight with a pine tree, don’t ignore it. Small skin issues can become larger problems over time.
With a little detective work—and sometimes a little trial and error—most people can find a solution that keeps both their glucose levels and their skin happy.
Because diabetes management is hard enough.
Your sensor shouldn’t be trying to attack you, too.
Talk to IDS!
The IDS clinical team has extensive experience helping people overcome skin issues related to their diabetes devices.
Before suffering another day, give us a call! 610-642-6055, option 1.
References:
[1] LeBoff MS, Greenspan SL, Insogna KL, Lewiecki EM, Saag KG, Singer AJ, Siris ES. The clinician’s guide to prevention and treatment of osteoporosis. Osteoporos Int. 2022 Oct;33(10):2049-2102. doi: 10.1007/s00198-021-05900-y. Epub 2022 Apr 28. Erratum in: Osteoporos Int. 2022 Oct;33(10):2243. doi: 10.1007/s00198-022-06479-8. PMID: 35478046; PMCID: PMC9546973.
[2] Voulgaridou G, Papadopoulou SK, Detopoulou P, Tsoumana D, Giaginis C, Kondyli FS, Lymperaki E, Pritsa A. Vitamin D and Calcium in Osteoporosis, and the Role of Bone Turnover Markers: A Narrative Review of Recent Data from RCTs. Diseases. 2023 Feb 8;11(1):29. doi: 10.3390/diseases11010029. PMID: 36810543; PMCID: PMC9944083.